Induction Machines & Speed Control
An induction motor develops torque from slip between a rotating stator field and rotor speed; voltage, frequency, flux, current, thermal state, and inverter limits jointly define usable operation.
Three-phase stator currents create a rotating magnetic field. For pole pairs at electrical frequency ,
Rotor conductors develop induced current only when their mechanical speed differs from the field. Slip is
At motoring load ; rotor electrical frequency is . Zero slip means no rotor induced frequency and, in the ideal induction mechanism, no torque.
Torque production and equivalent circuit #
The air gap behaves like a transformer whose secondary frequency changes with slip. Stator resistance/leakage, magnetizing reactance, and rotor resistance/leakage referred to the stator predict current, power factor, torque, and losses. Rotor copper loss is approximately slip times air-gap power, which explains why high slip means heat.
Starting #
At standstill , rotor frequency equals stator frequency and current can be large. Direct-on-line starting must fit supply voltage dip, contactor duty, motor starting capability, driven-load acceleration torque, and thermal limit. Star-delta and autotransformer methods reduce voltage and therefore reduce induction torque roughly with voltage squared; they are not free current reduction.
Scalar control #
Back EMF is approximately proportional to frequency times flux. Holding roughly constant maintains flux below base speed, with a low-speed voltage boost to overcome resistance. Above base frequency, inverter voltage is limited, flux weakens, and available torque falls while approximate constant-power operation may continue.
Open-loop does not directly regulate torque-producing current or compensate slip. It is adequate for many fans and pumps, not precise low-speed torque.
Field-oriented control #
FOC transforms measured phase currents into a rotating – frame aligned with estimated rotor flux. One current component controls flux and the orthogonal component controls torque, recovering DC-machine-like control. The transformations are simple; accurate flux angle, motor parameters, current sampling, dead-time compensation, and voltage limits are the hard parts.
Diagnostic map #
| Symptom | Check |
|---|---|
| high no-load current | wiring, voltage/frequency, saturation, parameter model |
| poor low-speed torque | stator drop, current limit, flux-angle estimate |
| trips on acceleration | ramp vs load inertia/torque, bus/current limits |
| overheats at low speed | current and rotor loss plus reduced shaft-fan cooling |
| speed oscillation | mechanical resonance, speed-loop bandwidth, estimator delay |
Commission in layers: phase order and insulation; current offsets and polarity; open-loop rotation; motor parameter/flux estimate; torque-current response; then speed and position loops.